metadata.dc.description.resumo: | O hidrômetro é o dispositivo que permite quantificar o volume de água por unidade de tempo que é destinado a residência e/ou empresa, e que permite monitorar o consumo de água aonde se faz necessário a realização de cobrança pelo uso ou mesmo para o monitoramento de seu uso, nos casos em que não há cobrança. O objetivo deste trabalho é identificar se a passagem de ar pelo hidrômetro causa alteração no monitoramento da vazão, bem como a eficiência de válvulas de retenção. A metodologia adotada abrangeu o levantamento de dados a partir de experimentos em laboratório, inserindo-se ar junto ao fluxo de água e anotados os valores mostrados nos hidrômetros e comparados com o recipiente graduado, sendo feito posteriormente uma análise estatística por meio de programa computacional. Após os ensaios, foi comprovado que o ar presente na rede causa alterações significativas na marcação dos hidrômetros, e a utilização da válvula de retenção não apresentou melhoras nas marcações dos hidrômetros em geral e apresentando piora na marcação em um dos hidrômetros. |
Abstract: | The hydrometer is the device that allows to quantify the volume of water per unit of time that is destined to the residence and/or company, and that allows to monitor the consumption of water where it is necessary to carry out a charge for the use or even for the monitoring of its use, in cases where there is no charge. The objective of this work is to identify if the passage of air through the hydrometer causes changes in the flow monitoring, as well as the efficiency of check valves. The adopted methodology included the collection of data from laboratory experiments, inserting air next to the water flow and recording the values shown in the hydrometers and compared with the graduated container, being later made a statistical analysis by means of a computer program. After the tests, it was proven that the air present in the network causes significant changes in the marking of the water meters, and the use of the check valve did not show improvement in the markings of the water meters in general and showing a worsening in the marking in one of the water meters. |
Keywords: | Ar na medição Conta de água Passagem de ar em hidrômetros Sistema de abastecimento Válvula de retenção |
metadata.dc.subject.cnpq: | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
metadata.dc.language: | por |
metadata.dc.publisher.country: | Brasil |
Publisher: | Instituto Federal Goiano |
metadata.dc.publisher.initials: | IF Goiano |
metadata.dc.publisher.department: | Campus Rio Verde |
metadata.dc.rights: | Acesso Restrito |
URI: | https://repositorio.ifgoiano.edu.br/handle/prefix/2411 |
Issue Date: | 21-Mar-2022 |
Appears in Collections: | Bacharelado em Engenharia Civil |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
tcc_Eduardo Henrique Mendes dos Santos Júnior.pdf | 1,53 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.