metadata.dc.type: | Trabalho de Conclusão de Curso |
Title: | ESTUDO DA NR10 E NBR5410 EM PAINÉIS ELÉTRICOS: ESTUDO DE CASO EM UMA INDÚSTRIA ALIMENTÍCIA |
metadata.dc.creator: | Melo, Jessyca Machado; Almeida, Jhéssicka Victoria Ferreira de |
metadata.dc.contributor.advisor1: | Fraga, Elio |
metadata.dc.description.resumo: | O tema abordado neste estudo destaca a importância da segurança do trabalho, ressaltando a necessidade de conformidade com as normas regulamentadoras em ambientes industriais. A relação entre segurança do trabalho e eficiência operacional é discutida, enfatizando a valorização de medidas preventivas para garantir um ambiente de trabalho seguro. O estudo de caso proposto visa examinar em como as normas NR-10 e NBR-5410 podem ser aplicadas de forma eficaz na readequação dos painéis elétricos industriais, que são identificados como componentes essenciais em ambientes industriais, responsáveis pela distribuição segura e controlada de energia elétrica. O trabalho se desenvolve em uma indústria de alimentos, onde os painéis antigos representavam riscos para os colaboradores devido à falta de conformidade com as recomendações de segurança. A pesquisa adota uma abordagem exploratória e qualitativa, utilizando informações de normas técnicas e literatura especializada. As melhorias propostas incluem a correção das não conformidades identificadas, como a adição de proteção contra partículas sólidas, identificação adequada dos cabos e implementação de botões de emergência para desarme em caso de incidente. Também, é sugerido uma adequação da planta industrial para garantir a segurança nas instalações elétricas, integrando medidas de controle com outras iniciativas da empresa para promover uma cultura organizacional de segurança. Este trabalho busca reduzir os riscos de acidente elétrico na atividade de manutenção, propondo soluções para aumentar a confiabilidade dos painéis industriais, alinhadas com as normas NBR 5410 e NR-10. Além disso, destaca-se a importância acadêmica deste estudo, que pode contribuir para o aprimoramento dos conhecimentos técnicos e científicos sobre segurança elétrica para futuros profissionais da engenharia elétrica, segurança do trabalho e áreas relacionadas. |
Abstract: | The topic addressed in this study highlights the importance of workplace safety, highlighting the need for compliance with regulatory standards in industrial environments. The relationship between workplace safety and operational efficiency is discussed, emphasizing the importance of preventive measures to ensure a safe working environment. The proposed case study aims to examine how the NR-10 and NBR5410 standards can be effectively applied in the retrofitting of industrial electrical panels, which are identified as essential components in industrial environments, responsible for the safe and controlled distribution of electrical energy. The work takes place in a food industry, where old panels posed risks to employees due to lack of compliance with safety recommendations. The research adopts an exploratory and qualitative approach, using information from technical standards and specialized literature. The proposed improvements include the correction of identified non-conformities, such as the addition of protection against solid particles, proper identification of cables and the implementation of emergency buttons to disarm in the event of an incident. Also, it is suggested to adapt the industrial plant to guarantee safety in electrical installations, integrating control measures with other company initiatives to promote an organizational culture of safety. This work seeks to reduce the risks of electrical accidents in maintenance activities, proposing solutions to increase the reliability of industrial panels, in line with standards NBR-5410 and NR-10. Furthermore, the academic importance of this study stands out, which can contribute to improving technical and scientific knowledge about electrical safety for future professionals in electrical engineering, occupational safety and related areas. |
Keywords: | Segurança do trabalho Painéis Elétricos Normas Regulamentadoras |
metadata.dc.subject.cnpq: | ENGENHARIAS::ENGENHARIA ELETRICA |
metadata.dc.language: | por |
metadata.dc.publisher.country: | Brasil |
Publisher: | Instituto Federal Goiano |
metadata.dc.publisher.initials: | IF Goiano |
metadata.dc.publisher.department: | Campus Trindade |
metadata.dc.rights: | Acesso Aberto |
URI: | https://repositorio.ifgoiano.edu.br/handle/prefix/5012 |
Issue Date: | 12-Dec-2024 |
Appears in Collections: | Bacharelado em Engenharia Elétrica |